59.¾µÏñÕóÁлòÕßRAIDÕóÁÐÖз¢Éú¹ÊÕϵĴÅÅÌÉϵÄËùÓÐÓû§Êý¾ÝºÍУÑéÊý¾ÝµÄÖØÐÂÉú³ÉµÄ ¹ý³Ì±»³ÆÎª£¨ B £©

A. ÖØ¼ÆËã B. ÖØ¹¹ C. Èȱ¸·Ý D. »Ö¸´ 60.¾ß±¸×î¼Ñ¶ÁдÐÔÄܵÄRAID¼¶±ðÊÇ£¨ C £©

A. RAID1 B. RAID3 C. RAID0 D. RAID5 61.ÒÔϲ»ÊDzÉÓÃÆæÅ¼Ð£Ñ鷽ʽ×÷ΪÊý¾ÝÈßÓ෽ʽµÄRAID¼¶±ðÊÇ£¨ A £©

A. RAID2 B. RAID3 C. RAID4 D. RAID5 62.¿ÉÒÔÖ§³ÖÒ»¸öRAID×éÖÐͬʱËð»µ2¸öÓ²ÅÌ£¬µ«ÊÇRAIDÖеÄÓÐЧÊý¾Ý²»»á¶ªÊ§£¬¿ÉÄÜ µÄRAID¼¶±ðÊÇ( BD )

A. RAID5 B. RAID6 C. RAID0 D. RAID10 63.ÏÂÁÐRAID×éÖÐÐèÒªµÄ×îСӲÅÌÊýΪ3¸öµÄÊÇ£º£¨ BC £©

A. RAID1 B. RAID3 C. RAID5 D. RAID10 64.ÏÂÁÐRAID¼¼ÊõÖвÉÓÃÆæÅ¼Ð£Ñ鷽ʽÀ´ÌṩÊý¾Ý±£»¤µÄÊÇ£º£¨ BC £©

A. RAID1 B. RAID3 C. RAID5 D. RAID10 65.ÏÂÁÐ˵·¨Öв»ÕýÈ·µÄÊÇ£º£¨ BD £©

A. Óɼ¸¸öÓ²ÅÌ×é³ÉµÄRAID³ÆÖ®ÎªÎïÀí¾í

B. ÔÚÎïÀí¾íµÄ»ù´¡ÉÏ¿ÉÒÔ°´ÕÕÖ¸¶¨ÈÝÁ¿´´½¨Ò»¸ö»ò¶à¸öÂß¼­¾í£¬Í¨¹ýLVN£¨Logic Volume Number£©À´±êʶ

C. RAID 5Äܹ»Ìá¸ß¶ÁдËÙÂÊ£¬²¢Ìṩһ¶¨³Ì¶ÈµÄÊý¾Ý°²È«£¬µ«Êǵ±Óе¥¿éÓ²Å̹ÊÕÏʱ£¬ ¶ÁдÐÔÄÜ»á´ó·ù¶ÈϽµ

D. RAID 6´Ó¹ãÒåÉϽ²ÊÇÖ¸Äܹ»ÔÊÐíÁ½¸öÓ²ÅÌͬʱʧЧµÄRAID¼¶±ð£¬ÏÁÒåÉϽ²£¬ÌØÖ¸ HPµÄADG ¼¼Êõ

66.ÔÚÑ¡Ôñ²ÉÓúÎÖÖRAIDÀàÐ͵Äʱºò£¬±ØÐë×¢ÒâÄÄЩÊÂÏ( ABCD ) A. Óû§Êý¾ÝÐèÒª¶àÉÙ¿Õ¼ä B. УÑé´øÀ´µÄ´ÅÅ̿ռäËðʧ

C. Ó¦ÓõÄÐÔÄÜÒªÇó D. ÔÚ´ÅÅ̹ÊÕÏʱ£¬´ÅÅ̵ÄÖØ½¨Ê±¼ä 67.³£¼û´ÅÅÌÕóÁеķÖÀà°üÀ¨£¨ ABD £©

A. JBOD B. SBOD C. MAID D. RAID 68.RAID6ÒýÈëÁ½¿éУÑéÅÌ£¬±£Ö¤ÔÚÁ½¿éÅÌͬʱ¹ÊÕÏʱÊý¾Ý²»¶ªÊ§¡£( ¡Ì ) 69.RAID01¼¼ÊõËüÊÇÏÈ×ö¾µÏñÈ»ºó×öÌõ´ø»¯¡£Ò»¸ö´ÅÅ̵ĶªÊ§µÈͬÓÚÕû¸ö¾µÏñÌõ´øµÄ¶ªÊ§£¬

ËùÒÔÒ»µ©¾µÏñʧ°Ü£¬Ôò´æ´¢ÏµÍ³³ÉΪһ¸öRAID-0ϵͳ£¨¡Á£©

70.RAID5ÔÚÊý¾ÝÖØ¹¹ÉϵŤ×÷¸ººÉºÍ»¨·ÑµÄʱ¼äÓ¦¸ÃÔ¶´óÓÚRAID10£¬¸ººÉ±ä´ó½«Ó°Öع¹

ÆÚ¼äµÄÐÔÄÜ£¬Ê±¼ä³¤ÒÔΪ×ÅÔٴγöÏÖÊý¾ÝË𻵵ĿÉÄÜÐÔ±ä´ó£¨¡Ì£© 71.RAID6ÒýÈëÁ½¿éУÑéÅÌ£¬±£Ö¤ÔÚÁ½¿éÅÌͬʱ¹ÊÕÏʱÊý¾Ý²»¶ªÊ§¡£(¡Ì ) 72.ÏÂÁÐ˵·¨´íÎóµÄÊÇ£º£¨ C £©

A. ÓÐIPµÄµØ·½£¬NASͨ³£¾Í¿ÉÒÔÌṩ·þÎñ

B. NASÊÍ·ÅÁËÖ÷»ú·þÎñÆ÷CPU¡¢ÄÚ´æ¶ÔÎļþ¹²Ïí¹ÜÀíͶÈëµÄ×ÊÔ´ C. NAS´æ´¢ÏµÍ³Ö»Äܱ»Ò»Ì¨Ö÷»úʹÓÃ

D. NASÔÚ´¦Àí·Ç½á¹¹»¯Êý¾Ý£¬ÈçÎļþµÈÐÔÄÜÓÐÃ÷ÏÔµÄÓÅÊÆ 73.ÏÂÁйØÓÚÎļþϵͳµÄ˵·¨£¬ÕýÈ·µÄÊÇ£¨ B £©

5

ÍøÂç´æ´¢Ìâ¿â£¬ÍÂѪÕûÀí£¬¸÷λºÃºÃ¿´°¡£¡

A£®Windows ϵͳÉϵÄNTFS¸ñʽµÄÎļþ£¬¿ÉÒÔÔÚAIX £¬Solaris £¬Linux µÈ²Ù×÷ϵͳ ÉÏ×ÔÓÉʹÓà B£®Îļþϵͳֱ½Ó¹ØÏµµ½Õû¸öϵͳµÄЧÂÊ£¬Ö»ÓÐÎļþϵͳºÍ´æ´¢ÏµÍ³µÄ²ÎÊý»¥ÏàÆ¥Å䣬 Õû¸öϵͳ²ÅÄÜ·¢»Ó×î¸ßµÄÐÔÄÜ

C£®ÎļþϵͳÊÇÈí¼þ£¬´æ´¢ÊÇÓ²¼þ£¬Á½ÕßûÓÐÈκιØÏµ D£®²»Í¬µÄ²Ù×÷ϵͳȱʡ¶¼²ÉÓÃÏàͬµÄÎļþϵͳ 74.ÄÄÀà´æ´¢ÏµÍ³ÓÐ×Ô¼ºµÄÎļþϵͳ£º£¨ B £©

A. DAS B. NAS C. SAN D. IP SAN 75.NASʹÓ㨠C £©×÷ΪÆäÍøÂç´«ÊäЭÒé¡£

A. FC B. SCSI C. TCP/IP D. IPX 76¡¢NAS¶ÔÓÚ£¨ B £©ÀàÐ͵ÄÊý¾Ý´«ÊäÐÔÄÜ×îºÃ¡£

A. ´ó¿éÊý¾Ý B. Îļþ C. С¿éÏûÏ¢ D. Á¬ÐøÊý¾Ý¿é

77¡¢Ïà¶ÔDAS¶øÑÔ£¬ÒÔϲ»ÊÇNASµÄÌØµãµÄÑ¡ÏîÊÇ£¨ C £©

A. NASÊÇ´ÓÍøÂç·þÎñÆ÷ÖзÖÀë³öÀ´µÄרÓô洢·þÎñÆ÷

B. NASϵͳµÄÓ¦Óòã³ÌÐò»úÆ÷ÔËÐнø³ÌÊÇÓëÊý¾Ý´æ´¢µ¥Ôª·ÖÀëµÄ C. NASϵͳÓëDASϵͳÏàͬ£¬¶¼Ã»ÓÐ×Ô¼ºµÄÎļþϵͳ

D. NASµÄÉè¼Æ±ãÓÚϵͳͬʱÂú×ã¶àÖÖÎļþϵͳµÄÎļþ·þÎñÐèÇó 78¡¢¶ÔNASÉ豸µÄÃèÊö£¬ÄĸöÊÇÕýÈ·µÄ?( B )

A. ÐèÒªÌØÊâµÄÏßÀÂÁ¬½Óµ½ÒÔÌ«ÍøÖÐ B. Á¬½Óµ½ÒÔÌ«ÍøÖÐʹÓñê×¼ÏßÀ C. ¿Í»§¶ËʹÓÿéÉ豸Êý¾Ý D. ÓÃÓÚÓ¦Óù²Ïí

79¡¢NASµÄÓ²¼þ×é¼þ°üÀ¨£¨ AB £©B¿Ï¶¨ÊǶԵ쬯äËû²»ÖªµÀ

A. ´æ´¢²¿·Ö£¬´Ë¹¦ÄÜÄ£¿éÌṩÁËÕæÕýµÄÎïÀí´æ´¢¿Õ¼ä£¬Ö÷Òª¼¼ÊõºÍЭÒé°üÀ¨RAID¡¢SCSI¡¢ SAS¡¢FC¡£

B. ¿ØÖÆÆ÷²¿·Ö£¬Ö÷ÒªÖ¸NAS»úÍ·²¿·Ö£¬Õⲿ·ÖÌṩÁËNASµ×²ãËùʹÓõÄÎļþϵͳ£¬ÒÔ¼° ³ÐÔØÎļþϵͳ¡¢¸÷ÖÖǰ¶ËЭÒéµÄ²Ù×÷ϵͳ¡£

C. ÍøÂ粿·Ö£¬Ö÷ÒªÌṩÁ˺ÍÓû§½»»¥µÄÍøÂçЭÒ飬Ö÷Òª°üÀ¨NFS¡¢CIFS¡¢FTPºÍHTTPµÈ£¬ Óû§×îÖÕͨ¹ýÕâЩЭÒé·ÃÎÊ´æ´¢¿Õ¼ä

D. ÐÄÌø²¿·Ö£¬Ö÷ÒªÊÇÌṩÁ˼¯Èº½ÚµãÖ®¼äµÄÐÄÌøÁ¬½Ó 80¡¢CIFSµÄÖ÷Ҫģ¿é°üÀ¨£º£¨ ABD £©

A. SMB B. NBT C. TCP/IP D. Browsing 81¡¢NAS Ìá¹©ÍøÂçÎļþ¹²Ïí¹¦ÄÜ£¬ÄÜʵÏÖÒ칹ƽ̨µÄÎļþ¹²Ïí£¬°²×°ºÍʹÓýÏΪ¼òµ¥£¬Æä Ö÷ÒªµÄЭÒé°üÀ¨£¨BC £©

A£®GFS B£®NFS C£®CIFS D£®NTFS 82¡¢NASµÄ³£ÓÃÁ¬½ÓЭÒé°üÀ¨£¨ AB £©

A£®NFS B£®CIFS C£®TCP D£®IP 83¡¢ÒÔÏÂÄÄЩ²»ÊÇNASµÄÓŵ㣿£¨ AD £©

A£®À©Õ¹ÐÔ±ÈSANºÃ B£®Ê¹Óüò±ã

C£®Õë¶ÔÎļþ¹²Ïí½øÐÐÓÅ»¯ D£®Õë¶Ô¿éÊý¾Ý´«Êä½øÐÐÓÅ»¯ 84¡¢NASµÄÌåϵ½á¹¹ÖаüÀ¨£¨ ABCD £©

A. ²Ù×÷ϵͳ B. Îļþϵͳ C. ÍøÂç½Ó¿Ú D. ´æ´¢×Óϵͳ 85¡¢NASµÄÈí¼þ×é¼þ°üÀ¨£¨ ABCD £©

6

ÍøÂç´æ´¢Ìâ¿â£¬ÍÂѪÕûÀí£¬¸÷λºÃºÃ¿´°¡£¡

A. ²Ù×÷ϵͳ B. Îļþϵͳ C. ÍøÂçÎļþ¹²Ïí D. ´æ´¢¹ÜÀí 86¡¢»ùÓÚÍøÂç²ãµÄ´æ´¢ÐéÄ⻯ÓÅÊÆÊÇÓëÖ÷»úÎ޹أ¬²»Õ¼ÓÃÖ÷»ú×ÊÔ´£¬ÕâÖÖ˵·¨ÊÇÕý(¡Ì)

87¡¢windowsϳ£¼ûÎļþϵͳ°üÀ¨ntfsºÍext3¡£ ( ¡Á)

88¡¢Í¨³£¶øÑÔ£¬NAS´«ÊäÎļþʱ¶ÔÒµÎñÍøÂçµÄÐÔÄÜûÓÐÓ°Ïì¡££¨ ¡Ì£© 89¡¢NASϵͳ¹¦ÄÜÇ¿´ó¡¢Ò×ÓÚÀ©Õ¹£¬ËùÒÔNASÍêÈ«¿ÉÒÔÌæ´úDAS¼Ü¹¹¡£(¡Ì) 90¡¢DAS¡¢FC-SAN¡¢IP-SAN¶¼Ö§³ÖµÄ°²È«´ëÊ©ÊÇ£¨ D £©

A. Zoning B. VLAN C. IP SEC VPN D. LUN mapping/masking

91¡¢´æ´¢ÇøÓòÍøÂ磨SAN£©°²È«µÄ»ù±¾Ë¼ÏëÊÇ£º£¨ C £©

A. °²È«ÉøÍ¸ÍøÂç B. ·º°²È«Ä£ÐÍ C. ÍøÂç¸ôÀë D. ¼ÓÃÜ 92¡¢¹ØÓÚÓ¦ÓÃϵͳºÍ´æ´¢µÄ¹ØÏµ£¬ÏÂÁÐ˵·¨ÕýÈ·µÄÊÇ£¨ C £©

A£®SAN ´æ´¢ÏµÍ³µÄ¼æÈÝÐÔ£¬ÓëÊý¾Ý¿âÃÜÇÐÏà¹Ø£¬²»Í¬µÄÊý¾Ý¿â£¬±ØÐë°²×°¶ÔÓ¦µÄ²¹¶¡£¬ ²ÅÄÜÕý³£Ê¹ÓÃ

B£®¶ÔÓÚÊý¾Ý¿â²ãÃæ£¬Êý¾ÝµÄÒ»ÖÂÐÔ±£Ö¤ÓÉÊý¾Ý¿âÈí¼þ×ÔÐб£ÕÏ£¬Óë´æ´¢ÎÞ C£®IT Ó¦Óü¼ÊõµÄ²»Í¬²ãÃæ¶Ô´æ´¢µÄ¹Ø×¢µã¸÷²»Ïàͬ£¬ÔÚ²Ù×÷ϵͳ²ã£¬Ö÷Òª¿¼ÂÇ´æ´¢µÄ ¼æÈÝÐÔ

D£®Óʼþϵͳ£¬ÊÓÆµµã²¥ÏµÍ³ÊôÓÚÓ¦ÓÃÈí¼þ£¬Óë´æ´¢ºÁÎÞ¹ØÏµ 93¡¢SANÊÇÒ»ÖÖ£¨ B £©

A. ´æ´¢É豸 B. רΪÊý¾Ý´æ´¢¶øÉè¼ÆºÍ¹¹½¨µÄÍøÂç C. ¹âÏ˽»»»»ú D. HBA

94¡¢ÒÔÏÂÄĸöÑ¡Ïî²»ÊÇSANÓëNASµÄ²îÒ죿£¨ C £©

A. NASÉ豸ӵÓÐ×Ô¼ºµÄÎļþϵͳ£¬¶øSANûÓÐ

B. NASÊʺÏÓÚÎļþ´«ÊäÓë´æ´¢£¬¶øSAN¶ÔÓÚ¿éÊý¾ÝµÄ´«ÊäºÍ´æ´¢Ð§Âʸü¸ß C. SAN¿ÉÒÔÀ©Õ¹´æ´¢¿Õ¼ä£¬¶øNAS²»ÄÜ

D. SANÊÇÒ»ÖÖÍøÂç¼Ü¹¹£¬¶øNASÊÇÒ»¸öרÓÃÐ͵ÄÎļþ´æ´¢·þÎñÆ÷ 95¡¢¹ØÓÚLUN¿½±´ÊµÊ©ÒÔÏÂ˵·¨ÕýÈ·µÄÊÇ£º( AB )

A. ´´½¨LUN¿½±´ÖпÉÑ¡ÔñÔöÁ¿»òÈ«Á¿ B. ´´½¨Íê³Éºó²»¿ÉÒÔÔÙÐÞ¸ÄÔöÁ¿»òÈ«Á¿

C. ´´½¨ºÃºóÐèÒªÊÖ¶¯µã»÷ͬ²½À´´¥·¢Êý¾ÝµÄͬ²½ D. ͬ²½µÄ¹ý³ÌÖв»¿ÉÒÔÍ£Ö¹

96¡¢ÔÚ´´½¨LUN¿½±´Ê±£¬Èç¹ûÔ´LUNµÄ´óСÊÇ500G,ÄÇôԶ³ÌÕóÁÐÒÔÏÂÈÝÁ¿µÄÄ¿±êLUN²»ÄÜÓà ÓÚLUN¿½±´µÄÊÇ£º( AB )

A. 300G B. 400G C. 500G D. 600G 97¡¢Ó봫ͳµÄ±¾µØ´æ´¢ºÍDAS´æ´¢Ïà±È½Ï£¬ÏÂÁÐÄÄЩÊôÓÚÏÖ´úÐÂÐÍSANÕóÁд洢µÄÖ÷ÒªÌØµã »òÓÅÊÆ£¿( ABC)

A. ÈÝÁ¿´ó B. ÐÔÄÜ¸ß C. Îȶ¨ÐԺà D. ²»¹Ø×¢À©Õ¹ÐÔ

98¡¢SANµÄ´«ÊäÀàÐͰüÀ¨£¨ BD £©

A. IP B. FC C. SAS D. SCSI 99¡¢SANÓÉÒÔÏÂÉ豸¹¹³É£¨ ACD £©

A. Ö÷»ú¶ËÁ¬½Ó¿¨ B. ´æ´¢É豸 C. Á¬½ÓÏßÀ D. Á´½ÓÉ豸 100¡¢Ëæ×ÅSANÍøÂç¼¼ÊõµÄ²»¶Ï·¢Õ¹£¬Ä¿Ç°ÒѾ­ÐγÉÁË£¨ ACD £©ÕâÈýÖÖÖ÷Á÷ÀàÐÍµÄ´æ´¢Çø ÓòÍøÂç¡£

7

ÍøÂç´æ´¢Ìâ¿â£¬ÍÂѪÕûÀí£¬¸÷λºÃºÃ¿´°¡£¡

A. IP-SAN B. IPX-SAN C. FC-SAN D. SAS-SAN 101¡¢SANÕë¶Ôº£Á¿¡¢ÃæÏòÊý¾Ý¿éµÄÊý¾Ý´«Ê䣬¶øNASÔòÌṩÎļþ¼¶µÄÊý¾Ý·ÃÎʺ͹²Ïí·þÎñ £¨¡Ì£©

102¡¢SANÌṩ¸øÓ¦ÓÃÖ÷»úµÄ¾ÍÊÇÒ»¿é佨Á¢ÎļþϵͳµÄ¡°ÐéÄâ´ÅÅÌ¡±¡£ÔÚÉÏÃæ½¨Á¢Ê²Ã´ÑùµÄ Îļþϵͳ£¬ÍêÈ«ÓÉÖ÷»ú²Ù×÷ϵͳȷ¶¨ £¨¡Ì£© 103¡¢ ÒÔϲÉÓô®Ðд«Ê䷽ʽµÄ×ÜÏß¼¼ÊõÊÇ£¨ B £©

A. ATA B. PCI-E C. PCI-X D. PCI 104¡¢PCI-E 1XµÄËÙÂÊΪ£¨ D £©

A. 1Gbps B. 1.5Gbps C. 2Gbps D. 2.5Gbps 105. Ïà¶ÔÓÚ²¢ÐÐ×ÜÏß¶øÑÔ£¬ÒÔϲ»ÊÇ´®ÐÐ×ÜÏßÓŵãµÄÊÇ£¨ D £©

A. ´®ÐÐ×ÜÏ߾߱¸¸üÇ¿µÄÄÚ²¿Ðźſ¹¸ÉÈÅÄÜÁ¦ B. ´®ÐÐ×ÜÏßÿ´ÎÄܹ»·¢Ë͵ÄÊý¾Ýλ¸ü¶à C. ´®ÐÐ×ÜÏßÿ´ÎÄܹ»½â¾öÐźÅŤÇúÎÊÌâ D. ´®ÐÐ×ÜÏßÏû³ýÁËÖ±Á÷Æ«ÒÆÎÊÌâ

106¡¢SAS1.0±ê×¼µÄÊý¾Ý´«ÊäÂÊΪ£¨ C £©

A. 1Gbps B. 2Gbps C. 3Gbps D. 4Gbps 107¡¢iSCSIÊÇʹÓã¨TCP £©Ð­Òé·â×°£¨ IP SCSI£©Ð­ÒéÖ¸ÁîºÍÊý¾Ý£¬ÊÇIP-SANʵÏֵľßÌå ·½Ê½ºÍЭÒéÖ®Ò»¡££¨ D £©

A. TCP/IP FC B. SAS FC C. FC SCSI D. TCP/IP SCSI

108¡¢FCЭÒéΪ£¨ C £©Ð­ÒéÕ»½á¹¹

A. 3²ã B. 4²ã C. 5²ã D. 6²ã 109¡¢ Êý¾ÝÖ¡ÊÇÔÚ£¨ C £©²ã·â×°Ðγɵġ£

A. FC-0 B. FC-1 C. FC-2 D. FC-3 110¡¢ ×ÜÏߵĴø¿íÈ¡¾öÓÚ£¨ AC £©

A. ´«Êäλ¿í B. Êý¾Ý´óС C. ´«Ê䯵ÂÊ D. ´«ÊäÀàÐÍ

111¡¢°´ÕÕ¹¦ÄÜ·ÖÀ࣬×ÜÏ߿ɷÖΪ£¨ ABC £©

A. Êý¾Ý×ÜÏß B. µØÖ·×ÜÏß C. ¿ØÖÆ×ÜÏß D. ÐźÅ×ÜÏß

112¡¢´æ´¢»·¾³´î½¨Íê³Éºó£¬ÆäÉϵç˳ÐòÕýÈ·µÄÊÇ £¨ B £© (1)½ÓͨӲÅÌ¿òµçÔ´ (2)½Óͨ¿ØÖÆ¿òµçÔ´ (3)½Óͨ»ú¹ñµçÔ´ (4)½Óͨ½»»»»úµçÔ´ (5)½ÓͨӦÓ÷þÎñÆ÷µçÔ´

A. 1-2-3-4-5 B. 3-1-2-4-5 C. 2-3-1-5-4 D. 5-3-1-2-4 113¡¢¶ÔÓÚ´æ´¢É豸°²×°»·¾³µÄ¹©µçÒªÇ󣬽»Á÷µçÔ´Ó¦¸ÃÎȶ¨ÔÚ£¨ C £©·¶Î§¡£ A. 180V-230V B. 190V-240V C. 200V-240V D. 210V-250V

114¡¢ Èç¹û´ÅÅÌÕóÁÐÅäÖÃÁËÖ±Á÷µçÔ´£¬Ôò»ú·¿Ó¦¸ÃÌṩÎȶ¨µÄ£¨ B £©·¶Î§µÄÖ±Á÷µçѹ¡£

A. -48V¡«-50V B. -48V¡«-60V C. -24V¡«-48V D. -24V¡«-30V

115¡¢´ÅÅÌÕóÁеÄÖ÷»ú½Ó¿ÚÀàÐͰüÀ¨ £¨ AC £©

8


ÍøÂç´æ´¢Ìâ¿â¼°´ð°¸(2).doc ½«±¾ÎĵÄWordÎĵµÏÂÔØµ½µçÄÔ
ËÑË÷¸ü¶à¹ØÓÚ£º ÍøÂç´æ´¢Ìâ¿â¼°´ð°¸(2) µÄÎĵµ
Ïà¹ØÍÆ¼ö
Ïà¹ØÔĶÁ
¡Á ÓοͿì½ÝÏÂÔØÍ¨µÀ£¨ÏÂÔØºó¿ÉÒÔ×ÔÓɸ´ÖƺÍÅŰ棩

ÏÂÔØ±¾ÎĵµÐèÒªÖ§¸¶ 10 Ôª

Ö§¸¶·½Ê½£º

¿ªÍ¨VIP°üÔ»áÔ± ÌØ¼Û£º29Ôª/ÔÂ

×¢£ºÏÂÔØÎĵµÓпÉÄÜ¡°Ö»ÓÐĿ¼»òÕßÄÚÈݲ»È«¡±µÈÇé¿ö£¬ÇëÏÂÔØÖ®Ç°×¢Òâ±æ±ð£¬Èç¹ûÄúÒѸ¶·ÑÇÒÎÞ·¨ÏÂÔØ»òÄÚÈÝÓÐÎÊÌ⣬ÇëÁªÏµÎÒÃÇЭÖúÄã´¦Àí¡£
΢ÐÅ£ºxuecool-com QQ£º370150219